Harmonic Distortion
In the UK, the industrial electrical supply is a three phase voltage sine wave – each phase is 120˚ apart operating at a frequency of 50Hz (or cycles per second).
In the UK, the industrial electrical supply is a three phase voltage sine wave – each phase is 120˚ apart operating at a frequency of 50Hz (or cycles per second).
IDS has been an ABB inverter partner since 1994 providing complete support and backup to ABB’s market leading products. We are proud to be an ABB VP (Value Provider).
In practice however, the mains is not a pure sine wave. Harmonic distortion is caused by special loads – non-linear loads – distort the shape of the voltage sine wave by adding harmonics distortion to the mains. A harmonic is a multiple of the fundamental frequency – in this case 50Hz; the second harmonic is at 100Hz; the third harmonic at 150Hz etc. These harmonic waveforms are added to the fundamental creating a distorted sine wave.
Examples of non-linear loads, items that are likely to cause harmonic distortion are: computer power supplies, fluorescent lamp controllers, industrial rectifiers and inverters.
The effect of harmonics on the mains is not good. The effects can be:
Harmonics can be reduced at source. IDS supply and install low harmonic drives which reduces the harmonics produced to practically zero.
If this is impractical, then we can fit Active Filters. These Filters measure the harmonics on a system and ‘squirt in’ anti-phase currents at the correct harmonic frequency to cancel out the harmonics, working in a similar manner to noise cancelling headphones.
Since inverters can cause harmonics, we at IDS are experienced and set up to monitor and record these harmonics to determine their levels. We simply carry out a week’s monitoring of the quality of the mains where it is effectively connected to the rest of the network. After analysis of these harmonics, we would then advise what action to take. This could be:
This would be detailed in a comprehensive report (see below) with the advised action plan.
Download ABB’s white paper on harmonics in the Water Industry here
You can see examples of Harmonic Distortion Surveys here